    Home > Products & Services > Closed Circuit Towers > PFi Series

    PFi Series

    3.Custom Features

    Date : 2019-09-05 19:01

    Material of Construction

    Standard construction

    G235 mill galvanized steel is the heaviest commercially available galvanized steel, universally recognized for its strength and corrosion resistance. To assure long life, G235 mill galvanized steel panels and structural members are used as the standard material of construction. BAC units are certified to withstand up to an SDS of 3.10g and wind loads of 200psf, proving its construction is designed for extreme durability. With proper maintenance and water treatment, G235 galvanized steel will provide an excellent service life under the operation conditions normally encountered in comfort cooling and industrial applications.

    Stainless steel (Option)

    Two stainless steel material of construction options are available. One is stainless cold water basin, all steel panels and structural members of the cold water basin are constructed from stainless steel and other panels and structural members of the units are still constructed from G235 galvanized steel, Another is all stainless steel construction, all steel panels and structural elements are constructed of stainless steel.

    Coil Configurations

    Standard serpentine coil

    The standard coil is constructed of continuous lengths of all prime surface steel. The coil is hot-dip galvanized after fabrication (HDGAF) to apply a thick, zinc corrosion barrier over the entire exterior surface of the coil. The coil is designed for low pressure drop and for free drainage of fluid. Each coil is pneumatically tested at 2.58MPa and is fabricated per ASME B31.5 standards to ensure the highest quality and complete integrity.

    Cleanable header coil (Option)

    The cleanable header tube bundle provides removable cover plates on the inlet and outlet header boxes to permit access to each serpentine tube circuit for solvent or air-pressure cleaning. Each coil is pneumatically tested at 860kPa.

    Stainless steel coil (Option)

    Coils are available in stainless steel for specialized applications. The coil is designed for low pressure drop and for free drainage of fluid. Each coil is pneumatically tested at 2.58MPa and is fabricated per ASME B31.5 standards to ensure the highest quality and integrity.

    image006

    Stainless Steel Coil Construction

    ASME U designator coil (Option)

    BAC offers coils that are certified in accordance with the ASME Boiler and Pressure Vessel Code, Section VIII, Division I. ASME U designated coils are available for projects requiring ASME certified pressure vessels and involve 3rd party inspection and certification. Standard ASME U designator coils are rated at 2.34MPa maximum allowable working pressure, and they are pneumatically tested at 2.58MPa.

    Multiple circuit coils (Option)

    Split coil configurations are available to allow separate process fluid loops through the same unit. Separate loops may be needed for multiple applications requiring different temperature processes or multiple types of process fluids.

    Drive System Options

    Standard BALTIDRIVE? power train

    The BALTIDRIVE? power train utilizes special corrosion resistant materials of construction and state-of-the-art technology to ensure ease of maintenance and reliable year-round performance. This BAC engineered drive system consists of a specially designed powerband and two cast aluminum sheaves located at minimal shaft centerline distances to maximize belt life. When compared to a gear drive system, this specially engineered belt drive system provides many advantages. The BALTIDRIVE? power train requires only periodic inspection of components and belt tensioning, which is simple with a single nut adjustment and requires less downtime. Belt drive systems also have the added advantage of being suitable for variable frequency drive (VFD) applications without requiring expensive optional accessories.

    image007

    BALTIDRIVE? Power Train

    Standard extended lubrication lines

    Extended lubrication lines are available for lubrication of the fan shaft bearings. Fitting are located on the exterior casing panel next to the access door.

    Independent fan operation (Option)

    Two fan PFi-1218 and PFi-1236 models are available for added redundancy and capacity control. The two fan drive system consists of one fan and drive assembly for each fan to allow independent operation.

    Vibration cutout switch (Option)

    A factory mounted vibration cutout switch is available to effectively protect against rotating equipment failure. BAC can offer either a mechanical or solid-state electronic vibration cutout switch in a NEMA 4 enclosure to ensure reliable protection. Additional contacts can be provided on either switch type to activate an alarm. Remote reset capacity is also available on either switch type.

    image009

    Vibration Cutout Switch

    Automatic bearing greaser (Option)

    Automatic bearing greasers come with BAC recommended grease, compatible with all BAC bearings and provide a continuous supply of new grease to eliminate the need for periodic bearing maintenance. Life of the bearing is extended by eliminating under and over greasing problems.

    image011

    Automatic Bearing Greaser

    Cold Water Basin

    Standard mechanical water level control

    Mechanical make-up valves must operate continuously in the moist and turbulent environment within evaporative cooling equipment. Due to this environment, the operation of the valve must be simple and the valve must be durable. BAC’s high quality mechanical water level control assembly is standard with all units and has been specially designed to provide the most reliable operation while being easy to maintain.

    image013

    Mechanical Water Level Control

    Electric water level control (Option)

    BAC’s electric water level control (EWLC) is a state-of-the-art, conductivity actuated, probe type liquid level control. The hermetically sealed EWLC is engineered and manufactured specifically for use in evaporative cooling systems and is equipped with an error code LED to indicate status, including when the water and/or proves are dirty. The EWLC option replaces the standard mechanical make-up valve and includes a slow closing, solenoid activated valve in the make-up water line to minimize water hammer. EWLC is recommended when more precise water level control is required and in areas that experience sub-freezing conditions.

    image015

    Electric Water Level Control

    Basin sweeper piping (Option)

    Basin sweeper piping is an effective method of eliminating sediment that may collect in the basin. A complete piping system, including nozzles, is provided in the basin to connect to side stream filtration systems.

    image017

    Basin Sweeper Piping

    Low and high level alarm float switch (Option)

    Low and high level alarm float switches are available to provide added control to your equipment operation. Level alarms can alert operators to and abnormal operating condition to ensure the highest system efficiency with minimal water usage.

    Basin heaters (Option)

    Evaporative cooling equipment exposed to below freezing ambient temperatures require protection to prevent freezing of the water in the cold water basin when the unit is idle. Factory-installed electric immersion heaters, which maintain 4.4°C water temperature, are a simple and inexpensive way of providing such protection.

    image019

    Basin Heater

    Sound Options

    Standard fan

    The fan provided for all PFi closed circuit cooling towers is selected to optimize low sound levels and maximize thermal performance. Thermal performance with the standard fan has been certified in accordance with CTI standard STD-201.

    Low sound fan (Option)

    The low sound fan option reduces sound level. Adding a high solidity fan allows for decreased fan speed, which proportionally decreases sound levels. Thermal performance with the low sound fan has been certified in accordance with CTI standard STD-201.

    image007

    Low Sound Fan

    Whisper quiet fan (Option)

    The whisper quiet fan reduces sound level further. This single piece, high solidity fan is made from chemical resistant fiber reinforced polyester (FRP) and comes standard with blade leading protection. As a single piece fan, the non-corrosive blades are permanently pitched and require minimal maintenance. Thermal performance with the whisper quiet fan has been certified in accordance with CTI standard STD-201.

    Water silencers (Option)

    Water silencers are available to reduce the sound of falling water inherent in induced draft counterflow evaporative cooling towers. Thermal performance with the water silencers has been certified in accordance with CTI standard STD-201.

    image022

    Water Silencers

    Air Discharge Options

    Fan cowl extensions (Option)

    Fan cowl extensions allow for unobstructed airflow on the discharge side, which help ensure that the units are providing maximum capacity. When closed circuit cooling towers cannot be located above adjacent structures, fan cowl extensions will be necessary so that discharge air flows out of the tower properly and is not circulated back toward the air intake by the combination of wind pressure and adjacent structures.

    Access Options

    Motor removal Davit (Option)

    All motor removal system options include davit arm(s) to facilitate motor replacement.

    image024

    Motor Removal Davit Arm

    Modular external platforms and ladder packages (Option)

    Every modular external platform is pre-assembled and pre-fitted at the factory to ensure that every component will fit and function exactly as described. The platform is rigged easily in the filed with minimum fasteners and drastically reduces the time required for rigging eternal access platforms.

    image026

    Modular External Platform with Ladder and Safety Cage

    ?
    主站蜘蛛池模板: 久久中精品中文字幕入口| 亚洲成人A√| 亚洲一级特黄大片一级特黄| 97超碰人人| 亚欧美闷骚院| 精品欧美一区二区在线观看| jizz中国jizz免费| 欧美激情视频一区二区三区免费| 色综合人人超人人超级国碰| 狠狠干天天撸| 丰满少妇人妻无码专区| 国产一区二区精品久久凹凸| 少妇愉情理伦片高潮日本| 人妻激情一区二区三区四区| 国产丰满乱子伦无码专区| 丰满岳乱妇久久久| yy19影院| 伊人久久大香线蕉AV色婷婷色| 色欲AV涩爱AV蜜芽AV三区| 草裙社区精品视频播放| 色综合天天综合网中文伊| 在线精品熟女AV播放| 亚洲综合一区二区三区| 国内精品视频一区二区三区八戒| 精选二区在线观看视频| 黑人成人网| 中文字幕亚洲精品人妻| chinese?国产?xxxx| 影音先锋亚洲激情天堂| 在线 欧美 中文 亚洲 精品| 欧美精品全部免费观看| 狠狠干狠狠草| 国产精品久久久久久无毒不卡| 99国产午夜福利在线观看| 口爆视频| 国产色婷婷精品综合在线 | 国产九色AV刺激露脸对白 | 丁香婷婷综合激情五月色| 色综合中文综合网| 亚洲AV无码一区二区三区波多野结衣| 亚洲国产成人无码AV在线影院L|